Baxi 600 System 2

Baxi 600 System 2 - System Boilers

System Boilers

Baxi 600 System 2

The Baxi 600 System 2 can be manually converted between natural gas or LPG without the need to purchase an accessory kit.

 

The system boiler is compatible with Megaflo and Baxi cylinders for that industry leading hot water performance. 

Features and Benefits

Multiple outputs

Available in outputs of 15, 18 & 24kW, natural gas or LPG

Safer and cleaner

Combined PrV with separate drain to facilitate a safer and clearer boiler drain down for repair

Time-saving

Colour-coded and removable wiring blocks to save time during installation

Quicker installation

Compatible with internal fit telescopic flue for a safer and quicker one-person fit installation from inside the property

Self-serve

Easy-Fill 2 permanent filling link enabling homeowner self-top up of system pressure to prevent engineer call outs
Show More
Show Less

Product Literature

Installation and Service Manuals

Installation and Service Manuals

User Guides

User Guides

Specification Guides

Specification Guides

Product Documentation

No documentation available.

Technical Specifications

Technical Specifications

Product Documentation

No documentation available.

Product Fiche

Product Fiche

Energy Labels

Baxi Duo-tec Compact Combi Boiler Dimensions

Dimensions

A: Boiler Width = 395mm

B: Boiler Height = 700mm

C: Boiler Depth = 285mm

D: Side Clearance = 2.5mm

E: Upper Clearance = 178mm

F: Lower Clearance = 200mm

G: Front Clearance = 5mm in operation (450mm for servicing)

Technical Specification

Product Model15 System18 System24 System
Product Code784472078447227844723
Gas
Natural gas or LPGNatural GasNatural GasNatural Gas
Inlet supply pressure (natural gas) (mbar (nominal))202020
Maximum Gas Rate (G20) Qmax (m³ / hr)1.641.962.61
Heat Input CH (kW (max) Gross (QnHs))17.220.627.4
Heat Input CH (kW (min) Gross (QnHs))5.25.25.2
Heat Output CH (non-condensing) (kW (Max) (Pn))151824
Heat Output CH (non-condensing) (kW (Min) (Pn))4.54.54.5
Heat Output CH (condensing) (kW (Max) (Pnc))16.219.425.8
Heat Output CH (condensing) (kW (Min) (Pnc))4.94.94.9
Heat Input domestic hot water (DHW) (kW max gross (QnwHs))N/AN/AN/A
Heat output domestic hot water (DHW) (kW max)N/AN/AN/A
Water heating efficiency classN/AN/AN/A
Electrical
Permanent live requiredYesYesYes
External fuse rating (on connection board) (Amps)333
Pump overrunYesYesYes
Integral 'boiler only' frost thermostatYesYesYes
Hydraulic
Maximum DHW flow rate (Delta T @ 35'C rise) (l/min)N/AN/AN/A
Minimum DHW flow rate required (l/min)N/AN/AN/A
Minimum operating DHW pressure required (bar)0.50.50.5
Integral expansion vessel (litres)777
Maximum capacity of the CH system (litres)100100100
Integral automatic bypassYesYesYes
Weights
Installer Lift Weight (kg)28.928.928.9

Contact your ASM

If you are a merchant or installer, your local Baxi representative is here to help.

More Information

Baxi combi Boiler - deconstructed

Baxi Genuine Parts

Whether you are working on an installation, repair or service, Baxi Genuine Parts are guaranteed for quality, reliability and safety. Start here to find the parts you need.
Baxi Boiler Training - Open Boiler 3

Product Training

Our training courses are held in our state-of-the-art training centres, several with CIPHE approval, by experienced, qualified engineers who know what the job is like.
Baxi Boiler Training Controls

Error Codes for Baxi Boilers

If a boiler develops a problem, it will display an error code. We explain the most common error codes here.  
Baxi Works App

Baxi Works

Baxi Works is our installer loyalty scheme, designed to prioritise you,support you and reward you for choosing Baxi.