The Baxi 400 Heat has no need for a pump overrun or permanent live to save time during installation.
This boiler can be installed on open vent or sealed systems and has an optional in-case rear flue for a neater installation.
Boilers
Heat Pumps
Cylinders
Heating Controls
Flues and Accessories
Commercial Solutions
Combi Boilers
Electric Boilers
Heat Only Boilers
System Boilers
Boilers
Heat Pump Training
Commercial Training

Product Training

Contact your ASM
Boilers
Cylinders
Heat Pumps
Flues & Accessories
Baxi 400 Heat

Heat Only Boilers
This boiler can be installed on open vent or sealed systems and has an optional in-case rear flue for a neater installation.
Whether you’re new to Baxi Works or already installing, extra installs mean extra rewards. Earn up to £250 in points when you fit qualifying Baxi 400 or Main Eco Compact boilers.

No documentation available.
No documentation available.
No documentation available.
No documentation available.
No documentation available.

A: Boiler Width = 370mm
B: Boiler Height = 625mm
C: Boiler Depth = 270mm
D: Side Clearance = 5mm
E: Upper Clearance = 190mm
F: Lower Clearance = 120mm
G: Front Clearance = 5mm in operation (500mm for servicing)
| Product Model | 15kW | 18kW | 24kW | 30kW |
|---|---|---|---|---|
| Product Code | 7668933 | 7668934 | 7668935 | 7668936 |
| Controls | ||||
| Operating mode selector switch with reset (Yes/No) | Yes | Yes | Yes | Yes |
| User adjustable CH temperature -Range - e.g. 30ºC to 80ºC (+/- 5ºC) | Yes | Yes | Yes | Yes |
| LED status/fault diagnosis display (Yes/nNo) | Yes | Yes | Yes | Yes |
| Gas | ||||
| SAP 2009 Annual Efficiency (PCDB/SEDBUK) % | 89.2 | 89.2 | 89.1 | 89.1 |
| NOx class (1-5) | 5 | 5 | 5 | 6 |
| ErP Product Information | ||||
| NOx (mg/kWh) | 20 | 21 | 23 | 21 |
| Sound Power Level, Indoors (LWA dB) | 33 | 34 | 35 | 49 |
| Space Heating Efficiency Class | A | A | A | A |
| Heat Input CH -kW max gross (QnHs) | 18.32 | 21.75 | 28.62 | 34.35 |
| Heat Input CH - kW min gross (QnHs) | 8.59 | 8.59 | 8.59 | 8.59 |
| Heat Output CH (non condensing) - kW max (Pn) | 16 | 19 | 25 | 30 |
| Heat Output CH (non condensing) - kW min (Pn) | 7.5 | 7.5 | 7.5 | 10.1 |
| Gas supply pipe size (mm) | 22 | 22 | 22 | 22 |
| Inlet supply pressure (natural gas) - mbar | 20 | 20 | 20 | 20 |
| Maximum gas rate (m3/hr) | 1.75 | 2.07 | 2.73 | 3.27 |
| Mechanical and hydraulic | ||||
| Compartment ventilation required | No | No | No | No |
| Flow / return pipe size (mm) | 22 | 22 | 22 | 22 |
| Condensate discharge pipe (mm) | 21.5 | 21.5 | 21.5 | 21.5 |
| Electrical | ||||
| Electrical supply - Volts/Hz | 230V/50Hz | 230V/50Hz | 230V/ 50Hz | 230V/ 50Hz |
| Permanent live required (Yes/No) | No | No | No | No |
| Switched live (Yes/No) | Yes | Yes | Yes | Yes |
| Electrical power cable fitted as standard (1m of 3 core) | Yes | Yes | Yes | Yes |
| Power consumption (Watts) | 20 | 23 | 33 | 44 |
| External fuse rating (Amps)3 | 3 | 3 | 3 | |
| Internal fuse rating | 1.6T | 1.6T | 1.6T | 1.6T |
| Boiler IP rating (electrical protection) -Approval category | IPX4D | IPX4D | IPX4D | IPX4D |
| Pump overrun (Yes/No) | No | No | No | No |
| Concentric flue system | ||||
| Standard telescopic concentric flue (Length in mm) | 315-500 | 315-500 | 315-500 | 315-500 |
| Standard in-case rear telescopic concentric flue (Length in mm) | 220-345 | 220-345 | 220-345 | 220-345 |
| Horizontal concentric (60/100mm) - Max equivalent length (m) | 6 | 6 | 6 | 6 |
| Horizontal concentric (60/100mm) - Reduction per 135º bend (m) | 0.5 | 0.5 | 0.5 | 0.5 |
| Horizontal concentric (60/100mm) - Reduction per 93º bend (m) | 1 | 1 | 1 | 1 |
| Weight | ||||
| Installer lift weight -Max (kg) | 17.4 | 17.4 | 17.4 | 19.5 |
| Gross packaged boiler weight (kg) | 21.5 | 21.5 | 21.5 | 21.5 |
If you are a merchant or installer, your local Baxi representative is here to help.




Baxi Works is our installer loyalty scheme, designed to prioritise you, support you and reward you for choosing Baxi.