Our Boilers

Baxi 100 Combi LPG

The Baxi 100 is a compact and reliable LPG boiler.

  • Features
  • Dimensions
  • uSense
Baxi 100 Combi LPG

Features

*Terms & conditions apply

Baxi 100 Combi LPG

Dimensions

  • Boiler width = 390mm
  • Boiler height = 700mm
  • Boiler depth = 300mm
  • Side clearance = 5mm
  • Upper clearance = 175mm
  • Lower clearance = 170mm
  • Front clearance = 5mm in operation, 450mm for servicing

Features

  • More control – schedule your heating to fit in with your lifestyle
  • More flexibility – control your heating from your smartphone or tablet
  • More savings – see how much energy you’re using. Enjoy maximum efficiency and manage your bills

Find an installer to get a price

Contact your local installer to get a free quote for this boiler.

See your local installers

Download user guide

For operation and maintenance advice, download the user guide.

Baxi 100 Combi LPG user guide

Compare with your boiler

Find out how much you could save by installing a new boiler.

Efficiency calculator

Installer Information

  • Technical Features
  • Technical Data Table
  • Technical Literature
  • Product Training
  • 24 and 28kW
  • LPG ready - conversion kit not needed
  • Vertical Packaging
  • 32.5 kg lift weight
  • Easy to install and service
  • Choice of Flue lengths

Baxi 100 Combi  124 Combi 128 Combi 
Sales Code

Boiler pack (boiler and standard flue)

Boiler only

124124    

112124        

128128

112128 

Controls

Concealed User Controls    Yes Yes 
Operating mode selector switch with reset    Yes Yes 
User adjustable DHW temperature Range - 35° to 60° (±5ºC) Yes Yes 
User adjustable CH temperature   Range - 25° to 80° (±5ºC) Yes  Yes 
Temp/status/fault diagnosis display   LCD display  LCD display 
Baxi room thermostat   Optional  Optional  
RF Digital 7 Day Programmable Roomstat (Single Channel)    Optional  Optional 
Baxi Plug-In 24hr Digital timer-100   Optional  Optional 
Nest Learning Thermostat   Optional   Optional 
Multifit Outdoor Sensor Kit   Optional   Optional 
Stand Off Kit - Compact   Optional   Optional 
Remote Secondary PRV Kit   Optional   Optional 
Filling Loop Kit   Optional   Optional 
SAP 2009 Annual Efficiency (PCDB/SEDBUK)  % 89.1  89.1 
NOx class   
ErP Product Information 
NOx mg/kWh 15 17
Sound Power Level, Indoors  LWA dB 49 50 
Space Heating Efficiency Class   
Water Heating Declared Load Profile    XL  XL 
Water Heating Efficiency Class   
Heat Input CH kW max gross (QnHs) 20.2  26.6 
kW min gross (QnHs)  3.8 4.3 
Heat Output CH (non condensing)   kW (Pn) 20 24 
 kW (Pn) 3.4 3.8
Heat Output CH (condensing) kW max (PnC)          21.2  25.3 
kW min (PnC)  3.7 4.1 
 Gas
Gas supply pipe size  (mm)  22  22 
Inlet supply pressure (natural gas) mbar (nominal) 20 20
Maximum gas rate (natural gas after 10 mins)   m3/hr  2.61  3.05
Mechanical and hydraulic  
Heat input domestic hot water (DHW) kW max gross (QnwHs) 27.4  32.1 
Heat output domestic hot water kW max  24 28 
Maximum DHW flow rate (Delta T @ 35ºC max) l/min  9.8 11.5
Minimum DHW flow rate required l/min   2.0 2.0 
Minimum operating DHW pressure required bar  0.15 0.15
Maximum DHW system pressure bar  8 8
Safety discharge pressure bar  3.0 3.0
Compartment ventilation required No No 
Flow / return pipe size (mm)  22  22 
Integral expansion vessel   Size (litres)  6
CH system inhibitor required    Yes  Yes 
Condensate discharge pipe size   (mm)  21.5  21.5 
Electrical  
Electrical supply   Volts/Hz  230V/50Hz  230V/50Hz  
Permanent live required     Yes  Yes 
Electrical power cable required core   3 x 0.75 3 x 0.75 
Power consumption when firing   Watts  85                 90 
External fuse rating Amps 
Internal fuse rating   AH  F2L  F2L 
Boiler IP rating (electrical protection) without integral timer fitted  Approval category   IPX5D  IPX5D 
Circulating pump exercise feature     Yes  Yes 
Pump overrun     Yes  Yes 
Integral 'boiler only' frost thermostat    Yes  Yes 
Concentric flue system 
Standard telescopic concentric flue Length in mm 315-500  315-500 
Horizontal concentric (60/100 mm)  Max equivalent length (m)  10  10 
Reduction per 135° bend (m)  0.5  0.5 
Reduction per 93° bend (m) 
Horizontal concentric (80/125mm)  Max equivalent length 20 20
Horizontal twin tube (80/80mm)   Reduction per 135° bend (m)  0.25  0.25 
Reduction per 93°bend (m)   0.5  0.5 
Weights 
Installer lift weight (boiler) Max (kg)  32.5  32.5
Gross packaged boiler weight  (kg)  36.5 36.5

 

 