Baxi EcoBlue System

Features

*Terms & conditions apply

**Except the 32kW model

Baxi EcoBlue System

Dimensions

  • Boiler width = 390mm
  • Boiler height = 700mm
  • Boiler depth = 295mm
  • Side clearance = 5mm
  • Upper clearance = 175mm
  • Lower clearance = 150mm
  • Front clearance = 5mm in operation, 450mm for servicing

Find an installer to get a price

Contact your local installer to get a free quote for this boiler.

See your local installers

Download user guide

For operation and maintenance advice, download the user guide.

Baxi EcoBlue System user guide

Compare with your boiler

Find out how much you could save by installing a new boiler.

Efficiency calculator

Installer Information

  • Technical Features
  • Technical Data Table
  • Technical Literature
  • Product Training
  • 12, 15, 18, 24, 28 and 32kW
  • Full wall mounting jig
  • Choice of flue lengths
  • Easy to install and service
  • 1 metre lead provided

Baxi EcoBlue System  12 15  18  24  28   32
Sales Code Boiler Only 

7219505

7219506 7219507 7219509 7219509 7219510

Controls

   
Concealed Used Controls    Yes Yes  Yes  Yes  Yes  Yes 
User adjustable DHW temperature Range - 25° to 80° Yes Yes  Yes  Yes  Yes  Yes 
Temp/status/fault diagnosis display   LCD
display 
LCD 
display 
LCD 
display 
LCD
display 
LCD
display 
LCD
display 
Baxi twin channel wired programmer   Optional   Optional  Optional  Optional  Optional   Optional  
Baxi room thermostat   Optional   Optional  Optional  Optional  Optional   Optional  
Baxi wired outdoor weather sensor      Optional   Optional  Optional  Optional  Optional   Optional  
Gas    
SAP 2009 Annual Efficiency (PCDB/SEDBUK)  % 89.1 89.1  89.1  89.1  89.1  89.1 
NOx class   
 ErP Product Information
 NOx  mg/kWh     20 16 16 24 22 24
 Sound Power Level, Indoors  LWA dB 55 55 53 56 53 56
 Space Heating Efficiency Class   A A A A A A
Heat Input CH kW max gross (QnHs) 13.3  16.6  20.0  26.6  31.1  35.5 
kW min gross (QnHs) 2.7  3.4  4.0  5.2  5.9  7.0 
Heat Output CH (non condensing)   kW max (Pn) 12.0 15.0  18.0  24.0  28.0  32.0 
 kW min (Pn) 2.3  3.0  3.5  4.6  5.1  6.1 
 Heat Output CH (condensing)  kW max (PnC) 12.7 15.9 19.0 25.4 29.6 33.9
 kW min (PnC) 2.5 3.3 3.8 4.9 5.6 6.6
Gas supply pipe size  (mm)  22  22  22  22  22  22 
Inlet supply pressure (natural gas) mbar 20 20 20 20 20  20 
Maximum gas rate (natural gas after 10 mins)  m3/hr  1.27  1.58  1.90  2.54  2.96  3.38 
Mechanical and hydraulic      
Safety discharge pressure bar  3.0 3.0 3.0 3.0

3.0

3.0 
Bypass required   No No No No No  No 
Compartment ventilation required No No No No No  No 
Flow/return pipe size (mm) 22 22 22 22 22  22 
Integral expansion vessel Size (litres) 8 8 8 8 10 
CH system inhibitor required   Yes Yes Yes Yes Yes  Yes 
Condensate discharge pipe size (mm) 21.5 21.5 21.5 21.5 21.5  21.5 
Electrical      
Electrical supply   Volts/Hz  230V/50Hz  230V/50Hz   230V/50Hz   230V/50Hz   230V/50Hz  230V/50Hz 
Permanent live required     Yes  Yes  Yes  Yes  Yes  Yes 
Electrical power cable fitted as standard 1m of 3 core   Yes Yes  Yes  Yes  Yes  Yes 
Power consumption when firing   Watts  75 80 80 85 90 90
External fuse rating Amps 
Internal fuse rating   AH  F2L  F2L  F2L  F2L  F2L  F2L 
Boiler IP rating (electrical protection) without integral timer fitted  Approval category   IPX5D  IPX5D  IPX5D  IPX5D  IPX5D  IPX5D 
Circulating pump exercise feature     Yes  Yes  Yes  Yes  Yes   Yes  
Pump overrun     Yes  Yes  Yes  Yes  Yes   Yes  
Integral 'boiler only' frost thermostat    Yes  Yes  Yes  Yes  Yes   Yes  
Concentric flue system     
Standard telescopic concentric flue Length in mm 315-500  315-500  315-500  315-500  315-500  315-500 
Horizontal concentric (60/100 mm)  Max equivalent length (m)  10  10  10  10  10  10 
Reduction per 135°bend (m)  0.5  0.5  0.5  0.5  0.5  0.5 
Reduction per 93° bend (m) 
Horizontal concentric (80/125mm)  Max equivalent length 20 20 20 20 20  20 
Twin pipe flue system      
Horizontal twin tube (80/80mm)  

Max equivalent length (both tubes in parallel) (m)

15  15  15  15  15  15 
Reduction per 135° bend (m)  0.25  0.25  0.25  0.25  0.25 0.25 
Reduction per 93°bend (m)   0.5  0.5  0.5  0.5  0.5  0.5 
Weights     
Installer lift weight   Max (kg)  32.5 32.5  32.5  32.5  34.5  37.5 
Gross packaged boiler weight  (kg)  37.1  37.1  37.1  37.1  39.1  43.2 

 

 