This fully-modulating boiler intuitively uses the right mount of fuel for its heat settings and is a great choice for homes with multiple bathrooms or low water pressure.
UNITS |
12 NG |
15 NG |
18 NG |
24 NG |
18 LPG |
24 LPG | |
Product code |
7750797 |
7750794 |
7750795 |
7750778 |
7750779 |
7750796 | |
Product Characteristics Database (PCDB) |
018742 |
018743 |
018744 |
018745 |
018746 |
018747 | |
CONTROLS |
|||||||
Reset button |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes | |
User adjustable Ch temperature |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes | |
LCD temp/ status / fault diagnosis display |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes | |
GAS |
|||||||
Gas (natural gas/ LPG) |
NG |
NG |
NG |
NG |
LPG |
LPG | |
Inlet supply pressure |
Mbar |
20 |
20 |
20 |
20 |
37 |
37 |
Maximum gas rate (natural gas) |
M³ / hr |
1.31 |
1.64 |
1.96 |
2.61 |
- |
- |
Maximum gas rate (LPG) | Kg / hr | - | - | - | - | 1.37 | 1.83 |
Heat input central heating CH |
kW max gross (QnHs) |
13.7 | 17.2 | 20.6 | 27.4 | 20.6 | 27.7 |
kW min gross (QnHs) |
5.2 | 5.2 | 5.2 | 5.2 | 5.2 | 5.2 | |
Heat output CH (non condensing) |
kW max (Pn) | 12 | 15 | 18 | 24 | 18 | 24 |
kW min (Pn) | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | 4.5 | |
Heat output CH (condensing) |
kW max (Pnc) | 12.9 | 16.2 | 19.4 | 25.9 | 19.4 | 25.9 |
kW min (Pnc) | 4.9 | 4.9 | 4.9 | 4.9 | 4.9 | 4.9 | |
ErP PRODUCT INFORMATION | |||||||
NOx | Mg / kWh | 24 | 29 | 30 | 28 | 30 | 28 |
NOx class | 6 | 6 | 6 | 6 | 6 | 6 | |
Sound power level, indoors | LWA dB | 44 | 46 | 48 | 51 | 48 | 51 |
Space heating efficiency class | A | A | A | A | A | A | |
Seasonal space heating energy efficiency | % | 93 | 93 | 93 | 93 | 93 | 93 |