Our Boilers

Baxi EcoBlue Advance Combi

The Baxi EcoBlue Advance Combi is a reliable and energy efficient boiler for any home.

  • Features
  • Dimensions
Baxi EcoBlue Advance Combi

Features

*Terms & conditions apply

Baxi EcoBlue Advance Combi

Dimensions

  • Boiler width = 450mm
  • Boiler height = 763mm
  • Boiler depth = 345mm
  • Side clearance = 5mm
  • Upper clearance = 175mm
  • Lower clearance = 150mm
  • Front clearance = 5mm in operation, 450mm for servicing

Find an installer to get a price

Contact your local installer to get a free quote for this boiler.

See your local installers

Download user guide

For operation and maintenance advice, download the user guide.

Baxi EcoBlue Advance Combi user guide

Compare with your boiler

Find out how much you could save by installing a new boiler.

Efficiency calculator

Installer Information

  • Technical Features
  • Technical Data Table
  • Technical Literature
  • Product Training
  • Easy to install
  • 24, 28, 33, 40 kW
  • Full wall mounting jig
  • Choice of flue lengths
  • Range of plug in timers
  • Front access to all parts
  • 1 metre lead provided
  • Compatible with uSense smart control using the 230v switch live

Baxi EcoBlue Advance Combi  24 28  33  40 
 Sales Code Boiler Only  7219515 7219516 7219517 7219518

Controls

Concealed Used Controls    Yes Yes  Yes  Yes 
User adjustable DHW temperature Range - 40° to 60° Yes Yes  Yes  Yes 
User adjustable CH temperature   Range - 25° to 80° Yes  Yes  Yes  Yes
Temp/status/fault diagnosis display   LCD display  LCD display  LCD display  LCD display 
Baxi plug-in mechanical timer     Optional  Optional   Optional  Optional 
Baxi plug-in technical timer     Optional  Optional  Optional  Optional 
Baxi wireless mechanical RF thermostat    Optional   Optional  Optional  Optional 
Baxi wired outdoor weather sensor -combi     Optional   Optional  Optional  Optional 
Baxi single channel wired programmable room thermostat    Optional   Optional  Optional  Optional 
Baxi single channel wired programmer     Optional   Optional  Optional  Optional 
Baxi room thermostat     Optional   Optional  Optional  Optional 
SAP 2009 Annual Efficiency (PCDB/SEDBUK)  % 89.1  89.1  89.1  89.1 
NOx class   
ErP Product Information
NOx  mg/kWh     22 20 24 24
Sound Power Level, Indoors  LWA dB 51 52 53 55
Space Heating Efficiency Class   A A A A
Water Heating Declared Load Profile   XL XL XXL XXL
Water Heating Efficiency Class   A A A A
Heat Input CH  kW max Gross(QnHs) 22.2 26.6 31.1 35.5
 kW min Gross (QnHs)         5.2 6.3 7.6 8.9
Heat Output CH (non condensing)  kW max (Pn) 20 24 28 32
 kW min (Pn) 4.6 5.5 6.6 7.8
Heat Output CH (condensing)  kW max (PnC) 21.2 25.3 29.6 33.9
 kW min (PnC) 4.9 6.0 7.1  8.4 
 Gas
Gas supply pipe size  (mm)  22  22  22  22 
Flow/return pipe size  (mm) 22  22  22  22 
Mechanical and hydraulic  
Domestic hot water (DHW) Input - kW (max) gross 27.4  32.1  37.7  45.7 
Input - kW (max) net  24.7 28.9  34.0  41.1 
Output - kW (max)   24 28  33 40 
Maximum DHW flow rate (Delta T @ 35°max) l/min  9.8  11.5  13.5  16.4 
Maximum DHW flow rate required   l/min  2.0* 2.0*  2.0*  2.0* 
Maximum operating DHW pressure required   bar  0.15  0.15  0.15  0.15
Maximum DHW system pressure   bar  8
Safety discharge pressure   bar  3.0 3.0  3.0   3.0
Compartment ventilation required    No  No  No  No 
Inlet supply pressure (natural gas)  mbar (nominal)  20  20  20  20 
Maximum gas rate (natural gas after 10 mins) m3/hr  2.61  3.05  3.59  4.35 
Temporary filling loop supplied     Yes  Yes  Yes  Yes 
Integral expansion vessel   Size (litres)  10  10 
CH system inhibitor required    Yes  Yes  Yes  Yes 
Condensate discharge pipe size   (mm)  21.5  21.5  21.5  21.5 
Electrical  
Electrical supply   Volts/Hz  230V/50Hz  230V/50Hz   230V/50Hz   230V/50Hz  
Permanent live required     Yes  Yes  Yes  Yes 
Electrical power cable fitted as standard 1m of 3 core   Yes Yes  Yes  Yes 
Power consumption when firing   Watts  85 90  95  100 
External fuse rating Amps  3
Internal fuse rating   AH  F2L  F2L  F2L  F2L 
Boiler IP rating (electrical protection) without integral timer fitted  Approval category   IPX5D  IPX5D  IPX5D  IPX5D 
Circulating pump exercise feature     Yes  Yes  Yes  Yes 
Pump overrun     Yes  Yes  Yes  Yes 
Integral 'boiler only' frost thermostat    Yes  Yes  Yes  Yes 
Concentric flue system 
Standard telescopic concentric flue Length in mm 315-500  315-500  315-500  315-500 
Horizontal concentric (60/100 mm)  Max equivalent length (m)  10  10  10  10 
Reduction per 135°bend (m)  0.5  0.5  0.5  0.5 
Reduction per 93° bend (m) 
Horizontal concentric (80/125mm)  Max equivalent length 20 20 20 20
Twin pipe flue system  
Horizontal twin tube (80/80mm)  

Max equivalent length (both tubes in parallel) (m)

15  15  15  15 
Reduction per 135° bend (m)  0.25  0.25  0.25  0.25 
Reduction per 93°bend (m)   0.5  0.5  0.5  0.5 
Weights 
Installer lift weight   Max (kg)  36.0  36.0  38.0  39.0 
Gross packaged boiler weight  (kg)  42.3  42.3  42.3  42.3 

 

 * Where low flow taps or fittings are intended to be used in DHW systems connected to Baxi combination boilers it is strongly recommended that the DHW flow rate does not fall below 2.5 l/min to ensure reliable operation.

 

 